  1 地块

  Land plot 地块形状:矩形或梯形

  Land shape: Rectangular or Trapezium.

  临街面至少80米Frontage-80m(min);通道不小于80米Access≥80m; 深度宜为120~250米Depth-120~250m;

  地块面积宜为25000sq.m.以上site area-25000sq.m(up).

  2 柱距

  Column grid spacing LOTUS专用独立建筑: 钢筋混凝土结构,柱网距离为10.8mx10.8m;若钢结构,柱网距离至少为10.8mx10.8m. 若Lotus店租用下层,业主在上层,单层店的柱网距离应保持在 10.8mx10.8m;若Lotus租用多层,柱网距离应保持在8.4x8.4m (见附件图号1)

  Lotus stand alone building for reinforced concrete structure, the column grid spacing should be 10.8mx10.8m; If steel structure, the column should have min 10.8mx10.8m. If Lotus store lease lower floors & landlord on upper floors, the column grid spacing for single storey supercenter should maintain at 10.8mx10.8m; If Lotus store lease mutiple floors, the column grid spacing for multiple floors should maintain at 8.4x8.4m.(Refer to Typical Drawing Figure No.1.)